The MVTX explosion-proof screen vibrators have been designed for use in industrial processes in a potentially explosive atmosphere. They are used for industrial processes on screens. The enclosure of these screen vibrators is equipped with increased thickness and joints to prevent the transmission of an internal explosion to the surrounding area. Explosion-proof screen vibrators bear the UL, cUL, ATEX and IECEx markings
General
Italvibras code601648
TypeMVT 15/7900-S08
SeriesMVT/MVTX
Poles4
Speed1800 rpm @60Hz / 1500 rpm @50Hz
Power supplythree-phase
Size90
Mechanical data
Static moment 50Hz [kgmm]3147
Static moment 60Hz [kgmm]2191
Centrifugal force 50Hz [kg]7930
Centrifugal force 60Hz [kg]7930
Centrifugal force 50Hz [kN]77.8
Centrifugal force 60Hz [kN]77.8
Weight 50Hz [kg]285
Weight 60Hz [kg]270
Electrical data
Power rating 50Hz [W]-
Power rating 60Hz [W]-
Max current 400V 50Hz [A]-
Max current 460V 60Hz [A]-
Ia/In 50Hz-
Ia/In 60Hz-
Dimensions
Fig.MV2
A [mm]1437
B [mm]399
C [mm]330
D [mm]800
D1 [mm]240
E [mm]280
Holes dia G [mm]22
Holes No.8
F [mm]58
H [mm]180
I [mm]120
dia L [mm]40
M [mm]-
M1 [mm]46.5
N [mm]171
N1 [mm]350
alpha60deg
Cable entryNPT 3/4"
Series features
Power supplyThree-phase voltage up to 690V (maximum 600V for cULus), 50Hz or 60Hz (fixed) or variable frequency drive from 20Hz to the base frequency with constant torque load profile.
Mechanical protectionIP66 according to IEC/EN 60529.
Insulation classClass F (155degC).
Ambient temperatureFrom -20degC to +40degC.
CasingMade in three parts. Central part in high-tensile aluminium alloy, external parts in aluminum or spheroidal cast iron.
Approvals series MVTXClass I, Groups CD. Class II, Groups EFG. Temp. Class T4 (135degC) (Amb. Temp. -20degC to +40degC). ATEX II2G Ex d IIB 120degC Gb, II 2D Ex tb IIIC T105degC Db (Amb. Temp. -20degC to +40degC). Ex d IIB 105degC Gb, Ex tb IIIC T105degC Db (Amb. Temp.-20degC to +40degC). Notes: Version with Amb. Temp. -20degC to +60degC and other temperature classes is available.
Approvals series MVTX-GClass I, Groups CD. Temp. Class T3 (200degC) (Amb. Temp. -20degC to +60degC). ATEX II2G Ex d IIB 150degC Gb (Amb. Temp. -20degC to +60degC). Ex d IIB 150degC Gb (Amb. Temp. -20degC to +60degC). Notes: Version with cULus temperature class 125degC (ATEX & IECEx) and T3C - 160degc (cULus) with thermal protection is available.
CertificatesIECEx UL 11.0043X; E129825; DEMKO 12 ATEX 1103487X; Eurasian Customs Union N TC RU C-IT.GB08.B.02190 (Cyrillic letters transliterated)
Notes
Catalogue notes* Working moment = 2 x static moment. MVT table has no certification columns. Dimensions from page 67 (printed 65). Ia/In = ratio between start-up current and maximum current. Several sizes are available with different mounting bolt patterns. Electrical values printed as "-".
Ordering
SourceItalvibras General Catalogue 07-2019, page 64
PricingRequest a quote