The MVSI-E series has been designed for use in industrial processes in environments with a potentially explosive atmosphere, due to the presence of explosive gas and dust, in compliance with ATEX Directive (94/9/EC). In particular, the MVSI-E series can be used in areas 1 and 2 (gas) and in areas 21 and 22 (dusts).
General
Italvibras code6E0472
TypeMVSI 3/5000E-S02
SeriesMVSI-E
Poles2
Speed3600 rpm @60Hz / 3000 rpm @50Hz
Power supplythree-phase
SizeAF70
Temp. class (G)T3
Temp. class (D)135 degC
Mechanical data
Static moment 50Hz [kgmm]515
Static moment 60Hz [kgmm]344
Centrifugal force 50Hz [kg]5187
Centrifugal force 60Hz [kg]4979
Centrifugal force 50Hz [kN]50.9
Centrifugal force 60Hz [kN]48.8
Weight 50Hz [kg]109
Weight 60Hz [kg]105
Electrical data
Max input power 50Hz [W] (T3)3000
Max input power 60Hz [W] (T3)3000
Power rating 50Hz [W] (T3)2600
Power rating 60Hz [W] (T3)2600
Max current 400V 50Hz [A] (T3)4.75
Max current 460V 60Hz [A] (T3)4.20
tE [s] (T3)5
Ia/In (T3)8.00
Dimensions
Fig.A
A [mm]560
B [mm]290
C [mm]310
D [mm]155
E [mm]255
Holes dia G [mm]25
Holes No.4
F [mm]90
H [mm]130
I [mm]137
L [mm]238
M [mm]210
N [mm]253
Cable entry threadM25x1.5
Series features
Power supplyThree-phase voltage from 220V to 690V, 50Hz or 60Hz; variable frequency (in presence of PTC thermistor) from 20Hz to the base frequency with constant torque load profile tipo PWM.
Polarity2, 4, 6 and 8 poles.
Centrifugal forceRange extended up to 11160 kgf. (109 kN), adjustable in a continuous linear mode with variation of the position of the eccentric weights.
Mechanical protectionIP 66 according to IEC/EN 60529.
Protection against mechanical impactsIK 08 according to IEC/EN 62262.
Insulation classClass F (155 degC).
Ambient temperatureFrom -20 degC to +40 degC, on request it is possible to have vibrators for max. ambient temperatures of +55 degC.
CasingIn high-tensile aluminium alloy up to size 60, in spheroidal cast iron for larger sizes.
CategoryII2D & II2G
Level of protectionEx tb IIIC T... degC Db
Temperature classsee tables
EC certificateLCIE 05 ATEX 6163 X
Zones of use21, 22
Notes
Catalogue notes* Working moment = 2 x static moment. tE (s) = set time tE from IEC/EN 60079-7. Ia/In = ratio between start-up current and maximum current. Several sizes are available with different mounting bolt patterns. Please contact sales office at Italvibras.
Ordering
SourceItalvibras General Catalogue 07-2019, page 28
PricingRequest a quote