The CDX explosion-proof vibrators have been designed for use in industrial processes in a potentially explosive atmosphere. The enclosure of the CDX vibrators is equipped with increased thickness and joints to prevent the transmission of an internal explosion to the surrounding area. The CDX series is characterized and enhanced by many different certifications, depending on the vibrator model.
General
Italvibras code600317
TypeCDX 3/2100-G/D
SeriesCDX
Poles2
Speed3600 rpm @60Hz / 3000 rpm @50Hz
Power supplythree-phase
Size50
Cert CSA-
Cert KCsyes
Cert ATEX/IECExyes
Cert EACyes
Cert cULusyes
Mechanical data
Static moment 50Hz [kgmm]209
Static moment 60Hz [kgmm]144
Centrifugal force 50Hz [kg]2114
Centrifugal force 60Hz [kg]2080
Centrifugal force 50Hz [kN]20.7
Centrifugal force 60Hz [kN]20.4
Weight 50Hz [kg]59.8
Weight 60Hz [kg]58.5
Electrical data
Max input power 50Hz [W]1000
Max input power 60Hz [W]1260
Power rating 50Hz [W]900
Power rating 60Hz [W]1095
Max current 400V 50Hz [A]1.71
Max current 460V 60Hz [A]1.85
Ia/In 50Hz6.95
Ia/In 60Hz7.19
Dimensions
Fig.X
A [mm]520
B [mm]279
C [mm]235
D [mm]140
E [mm]190
Holes dia G [mm]22
Holes No.4
F [mm]18
H [mm]116
I [mm]134
L [mm]210
M [mm]246
N [mm]225
P [mm]140
Q [mm]80
R [mm]-
Capacitor 220V 50Hz [uF]-
Capacitor 115V 60Hz [uF]-
Cable entryNPT 3/4"
Series features
Power supplyThree-phase voltage from 24V to 690V (limit at 600V for UL and CSA certifications), 50Hz or 60Hz, or single-phase 100-130V 60Hz and 200-240V 50Hz; suitable for use with a PWM inverter from 20Hz to the base frequency with constant torque load profile.
Mechanical protectionIP66 according to IEC/EN 60529.
Insulation classClass F (155degC).
Ambient temperatureFrom -20degC to +40degC. See also approval table for other ambient temperatures.
CasingIn high-tensile aluminium alloy up to size 30, in spheroidal cast iron for larger sizes.
Approvals series CDXClass I, Groups CD. Class II, Groups EFG. Temp. Class T4 (135degC) (Amb. Temp. -20degC to +40degC). ATEX II2G Ex d IIB 120degC Gb, II 2D Ex tb IIIC T120degC Db (Amb. Temp. -20degC to +40degC). Ex d IIB 120degC Gb, Ex tb IIIC T120degC Db (Amb. Temp.-20degC to +40degC). Notes: Version with Amb. Temp. -20degC to +60degC and other temperature classes is available.
Approvals series CDX-GClass I, Groups CD. Temp. Class T2C (230degC) (Amb. Temp. -20degC to +60degC). ATEX II2G Ex d IIB 160degC Gb (Amb. Temp. -20degC to +60degC). Ex d IIB 160degC Gb (Amb. Temp. -20degC to +60degC). Notes: Version with cULus temperature class T3C (160degc) with thermal protection is available.
CertificatesLR 100948; E129825; DEMKO 07 ATEX 0612032X; IECEx UL 09.0034X; Eurasian Customs Union N TC RU C-IT.GB08.B.02190 (Cyrillic letters transliterated); KOSHA Korea Certificati n 11-AV4BO-0353/4/5/6/7/8/60
Notes
Catalogue notes* Working moment = 2 x static moment. Certification columns (icons): CSA (blue), KCs Korea (white), ATEX + IECEx (red + green, one column), EAC (light blue), cULus (lime); 'yes' = bullet printed, '-' = no bullet. Dimensions from page 61 (printed 59). Ia/In = ratio between start-up current and maximum current. Several sizes are available with different mounting bolt patterns.
Ordering
SourceItalvibras General Catalogue 07-2019, page 58
PricingRequest a quote