The MTF-E series has been designed for use in industrial processes in environments with a potentially explosive gas and dust atmosphere, in compliance with ATEX Directive (94/9/CE). In particular, the MTF-E series can be used in areas 1 and 2 (gas) and areas 21 and 22 (dusts).
General
Italvibras code6E0369
TypeMTF 3/200E-S02
SeriesMTF-E
Poles2
Speed3600 rpm @60Hz / 3000 rpm @50Hz
Power supplythree-phase
Size01
Temp. class (G)T3
Temp. class (D)120 degC
Mechanical data
Centrifugal force (A/B) 50Hz [kg]102/102
Centrifugal force (A/B) 60Hz [kg]117/117
Centrifugal force (A/B) 50Hz [kN]1.00/1.00
Centrifugal force (A/B) 60Hz [kN]1.15/1.15
Weight 50Hz [kg]7.50
Weight 60Hz [kg]7.30
Electrical data
Max input power 50Hz [W] (T3)180
Max input power 60Hz [W] (T3)180
Power rating 50Hz [W] (T3)120
Power rating 60Hz [W] (T3)120
Max current 400V 50Hz [A] (T3)-
Max current 460V 60Hz [A] (T3)-
tE [s] (T3)30
Ia/In (T3)2.68
Dimensions
Fig.G
A [mm]226
dia B [mm]211.5
dia C [mm]93
Holes dia D [mm]188
Holes dia H [mm]12
Holes N.4
E [mm]144
F [mm]20(50Hz)/16(60Hz)
G [mm]10
I [mm]58
L [mm]103
M [mm]23.5
dia P [mm]-
Cable entry threadM20x1.5
Seal gOR 4650
Series features
Power supplyThree-phase voltage from 120V to 690V, 50Hz or 60Hz; variable frequency (in presence of PTC thermistor) from 20Hz to the base frequency with constant torque load profile type PWM.
Polarity2 and 4 poles.
Insulation classClass F (155 degC).
Mechanical protectionIP 66 according to IEC/EN 60529; mechanical protection is ensured in the mounting phase of the vibrator onto the vibrating machine, by introducing the special seal into the seat on the coupling flange.
Protection against mechanical impactsIK 08 according to IEC/EN 62262.
Ambient temperatureFrom -20 degC to +40 degC, on request it is possible to have vibrators for max. ambient temperatures of +55 degC.
CasingIn high-tensile aluminium alloy up to size 50, in spheroidal cast iron for size 70.
CategoryII2D & II2G
Level of protectionEx tb IIIC T... degC Db
Temperature classsee tables
EC certificateLCIE 05 ATEX 6163 X
Zones of use21, 22
Notes
Catalogue notes* Listed as A/B: total centrifugal force is the sum of centrifugal force of top weights (A) and centrifugal force of bottom weights (B).; (circle) Available only in versions 127/220V 50Hz three-phase, 200/346V 50Hz three-phase and 210/363V 60Hz three-phase.; Dimensions from PDF p79 (printed 77). tE (s) = set time tE from IEC/EN 60079-7. Ia/In = ratio between start-up current and maximum current.
Ordering
SourceItalvibras General Catalogue 07-2019, page 76