The MVSS stainless steel series vibrators are characterized by their total protection from liquids, dusts, aggressive agents and contaminants, thanks to the stainless steel casing and external components
General
Italvibras code600329
TypeMVSS 3/200-S02
SeriesMVSS
Poles2
Speed3600 rpm @60Hz / 3000 rpm @50Hz
Power supplythree-phase and single-phase
Size01
CSAyes
Mechanical data
Static moment 50Hz [kgmm]20.2
Static moment 60Hz [kgmm]16.2
Centrifugal force 50Hz [kg]203
Centrifugal force 60Hz [kg]234
Centrifugal force 50Hz [kN]1.99
Centrifugal force 60Hz [kN]2.29
Weight 50Hz [kg]8.20
Weight 60Hz [kg]8.00
Electrical data
Max input power 50Hz [W]180
Max input power 60Hz [W]180
Max current 400V 50Hz [A]0.35
Max current 460V 60Hz [A]0.30
Ia/In 50Hz2.68
Ia/In 60Hz3.00
Single-phase electrical data
Single-phase Max input power 50Hz [W]165
Single-phase Max input power 60Hz [W]165
Single-phase Max current 220V 50Hz [A]0.75
Single-phase Max current 115V 60Hz [A]1.52
Single-phase Ia/In 50Hz1.67
Single-phase Ia/In 60Hz2.24
Dimensions
Fig.W
A [mm]225
B [mm]151
C [mm]125
D [mm]62-74**
E [mm]106
Holes dia G [mm]9
Holes No.4
F [mm]10
H [mm]61
I [mm]53
L [mm]100
M [mm]100
N [mm]117
Capacitor 220V 50Hz [uF]-
Capacitor 115V 60Hz [uF]-
Cable entry threadM20x1.5
Single-phase dimensions (mm)
Capacitor 220V 50Hz [uF]10
Capacitor 115V 60Hz [uF]35
Series features
Power supplyThree-phase voltage from 24V to 690V, 50Hz or 60Hz or single-phase 100-130V, 60Hz and 200-240V, 50Hz (single-phase types are supplied without capacitor); suitable for use with an inverter from 20Hz to the base frequency with constant torque load profile.
Mechanical protectionIP 66 according to IEC/EN 60529.
Insulation classClass F (155degC), class H (180degC) on request.
Ambient temperatureFrom -20degC to +40degC. Versions for higher or lower temperatures are available on request.
CasingIn stainless steel AISI 304, ball burnishing surface treated to make the surface more hydrophobic.
CategoryII2D
Level of protectionEx tD A21 T...degC IP66 (Ex tb IIIC T...degC Db)
Temperature classsi veda tabella
EC certificateLCIE 05 ATEX 6163 X
Zones of use21, 22
Notes
Catalogue notes* Working moment = 2 x static moment. Dimensions from page 45 (printed 43). Ia/In = ratio between start-up current and maximum current. ** Slot.
Ordering
SourceItalvibras General Catalogue 07-2019, page 42
PricingRequest a quote