The MVB-E flanged vibrator series have been designed for use in industrial processes with screens and sieves in environments with a potentially explosive atmosphere, caused by gas and dusts, in compliance with ATEX Directive (94/9/EC). In particular, these vibrators can be used in areas 1 and 2 (gas) and in areas 21 and 22 (dusts).
General
Italvibras code6E1226
TypeMVB 1510/15-E
SeriesMVB-E
Poles4
Speed1800 rpm @60Hz / 1500 rpm @50Hz
Power supplythree-phase
Size50
Available versionsB, C, D
Temp. class (G)T3, T4
Temp. class (D)150 degC
Mechanical data
Centrifugal force 50Hz [kg]1500
Centrifugal force 60Hz [kg]1500
Centrifugal force 50Hz [kN]14.7
Centrifugal force 60Hz [kN]14.7
Weight [kg]41.5
Electrical data
Max input power 50Hz [W] (T3)1100
Max input power 60Hz [W] (T3)1150
Power rating 50Hz [W] (T3)730
Power rating 60Hz [W] (T3)800
Max current 400V 50Hz [A] (T3)1.90
Max current 460V 60Hz [A] (T3)1.82
tE [s] (T3)9
Ia/In (T3)4.95
Max input power 50Hz [W] (T4)630
Max input power 60Hz [W] (T4)700
Power rating 50Hz [W] (T4)480
Power rating 60Hz [W] (T4)530
Max current 400V 50Hz [A] (T4)1.33
Max current 460V 60Hz [A] (T4)1.27
tE [s] (T4)5.5
Ia/In (T4)7.00
Dimensions
Fig.I
A [mm]476
dia B [mm]290
dia C [mm]171
Holes dia D [mm]250
Holes dia H [mm]17
Holes N.6
E [mm]278
F [mm]46
G [mm]20
I [deg]35
L [mm]71
M or dia N (ambiguous position) [mm]71
PressacavoM25x1.5
Series features
Power supplyThree-phase voltage from 220V to 690V, 50Hz or 60Hz; variable frequency (in presence of PTC thermistor) from 20Hz to the base frequency with constant torque load profile type PWM.
Polarity4 poles.
Insulation classClass F (155 degC).
Mechanical protectionIP 66 according to IEC/EN 60529.
Protection against mechanical impactsIK 08 according to IEC/EN 62262.
Ambient temperatureFrom -20 degC to +40 degC, on request it is possible to have vibrators for max. ambient temperature +55 degC.
CasingIn spheroidal cast iron to have high strength and optimal elasticity.
TipoMVB-E gr.50, MVB-E-FLC gr.50
CategoryII 2D & II 2G
Level of protectionEx tb IIIC T150 degC Db; Ex e IIC T3/T4 Gb
Temperature classGas: T3 (200 degC o T4 (135 degC); Polveri: 150 degC
Zones of use1, 2, 21, 22
Notes
Catalogue notesVersions: A basic model; B basic model with angle disc; C with angle disc and weights type C (clamped); D with angle disc and weights type D (lamellar).; (*) The lifting rings are obtained in the casing, there are no eyebolts on the shaft.; Dimensions from PDF p91 (printed 89); dimension-table type printed with '*'. tE (s) = set time tE from IEC/EN 60079-7. Ia/In = ratio between start-up current and maximum current. Column header printed as 'I deg' (MVB p87 prints this column as 'dia I' with the same 35). Value 71 printed centred between M and dia N columns; not assigned.
Ordering
SourceItalvibras General Catalogue 07-2019, page 88
PricingRequest a quote