The MVSI-E series has been designed for use in industrial processes in environments with a potentially explosive atmosphere, due to the presence of explosive gas and dust, in compliance with ATEX Directive (94/9/EC). In particular, the MVSI-E series can be used in areas 1 and 2 (gas) and in areas 21 and 22 (dusts).
General
Italvibras code6E2381
TypeMVSI 10/1110E-S08
SeriesMVSI-E
Poles6
Speed1200 rpm @60Hz / 1000 rpm @50Hz
Power supplythree-phase
Temp. class (G)T3, T4
Size50
Temp. class (D)135 degC
Mechanical data
Static moment 50Hz [kgmm]1012
Static moment 60Hz [kgmm]715
Centrifugal force 50Hz [kg]1132
Centrifugal force 60Hz [kg]1151
Centrifugal force 50Hz [kN]11.1
Centrifugal force 60Hz [kN]11.3
Weight 50Hz [kg]55.8
Weight 60Hz [kg]48.8
Electrical data
Max input power 50Hz [W] (T3)750
Max input power 60Hz [W] (T3)690
Power rating 50Hz [W] (T3)550
Power rating 60Hz [W] (T3)550
Max current 400V 50Hz [A] (T3)1.57
Max current 460V 60Hz [A] (T3)1.36
tE [s] (T3)19
Ia/In (T3)3.33
Max input power 50Hz [W] (T4)480
Max input power 60Hz [W] (T4)500
Power rating 50Hz [W] (T4)300
Power rating 60Hz [W] (T4)300
Max current 400V 50Hz [A] (T4)1.24
Max current 460V 60Hz [A] (T4)1.00
tE [s] (T4)13
Ia/In (T4)4.23
Dimensions
Fig.A
A [mm]574
B [mm]244
C [mm]230
D [mm]140
E [mm]190
Holes dia G [mm]17
Holes No.4
F [mm]45
H [mm]116
I [mm]171
L [mm]207
M [mm]190
N [mm]225
Cable entry threadM25x1.5
Series features
Power supplyThree-phase voltage from 220V to 690V, 50Hz or 60Hz; variable frequency (in presence of PTC thermistor) from 20Hz to the base frequency with constant torque load profile tipo PWM.
Polarity2, 4, 6 and 8 poles.
Centrifugal forceRange extended up to 11160 kgf. (109 kN), adjustable in a continuous linear mode with variation of the position of the eccentric weights.
Mechanical protectionIP 66 according to IEC/EN 60529.
Protection against mechanical impactsIK 08 according to IEC/EN 62262.
Insulation classClass F (155 degC).
Ambient temperatureFrom -20 degC to +40 degC, on request it is possible to have vibrators for max. ambient temperatures of +55 degC.
CasingIn high-tensile aluminium alloy up to size 60, in spheroidal cast iron for larger sizes.
CategoryII2D & II2G
Level of protectionEx tb IIIC T... degC Db
Temperature classsee tables
EC certificateLCIE 05 ATEX 6163 X
Zones of use21, 22
Notes
Catalogue notes* Working moment = 2 x static moment. tE (s) = set time tE from IEC/EN 60079-7. Ia/In = ratio between start-up current and maximum current. Several sizes are available with different mounting bolt patterns. Please contact sales office at Italvibras.
Ordering
SourceItalvibras General Catalogue 07-2019, page 32
PricingRequest a quote