The MVSI-TS series, obtained directly from the MVSI series, is characterized by the split weight covers. The weight cover is divided into two halves that can be removed in a radial direction. According to requirements it is possible to mount one or two split weight covers. The MVSI-TS series is indispensable in those applications where the position of the vibrator in the vibrating machine makes it difficult to axially remove the weight cover, while it has space to carry this out in a radial direction. The MVSI-TS series complies with the most recent IEC and EN international standards for use in atmospheres with potentially explosive powders. In particular, the MVSI-TS series can be used in areas 21 and 22.
General
Italvibras code602230
TypeMVSI 10/3000-S02-TS
SeriesMVSI-TS
Poles6
Speed1200 rpm @60Hz / 1000 rpm @50Hz
Power supplythree-phase
Size70
CSAyes
Mechanical data
Static moment 50Hz [kgmm]2690
Static moment 60Hz [kgmm]1940
Centrifugal force 50Hz [kg]3007
Centrifugal force 60Hz [kg]3124
Centrifugal force 50Hz [kN]29.5
Centrifugal force 60Hz [kN]30.6
Weight 50Hz [kg]146
Weight 60Hz [kg]131
Electrical data
Max input power 50Hz [W]2200
Max input power 60Hz [W]2400
Max current 400V 50Hz [A]4.50
Max current 460V 60Hz [A]4.30
Ia/In 50Hz4.35
Ia/In 60Hz4.81
Dimensions
Fig.P
A (1 split cover) [mm]741
A (2 split covers) [mm]770
B [mm]321
C [mm]310
D [mm]155
E [mm]255
Holes dia G [mm]23.5
Holes No.4
F [mm]77
H [mm]157
I [mm]201
L [mm]277
M [mm]215
N [mm]295
I1 [mm]230
N1 [mm]326
Cable entry threadM25x1.5
Series features
Power supplyThree-phase voltage from 48V to 690V, 50Hz or 60Hz; suitable for use with an inverter from 20Hz to the base frequency, with constant torque load profile.
Polarity4, 6 and 8 poles.
Centrifugal forceRange extended up to 30500 kgf. (300 kN), with centrifugal force adjustable by varying eccentric weights position..
Mechanical protectionIP 66 according to IEC/EN 60529.
Protection against mechanical impactsIK 08 according to IEC/EN 62262.
Insulation classClass F (155 degC), class H (180 degC) on request.
Ambient temperatureFrom -20 degC to +40 degC. Versions for higher or lower temperatures are available on request.
CasingIn high-tensile aluminium alloy up to size 60, in spheroidal cast iron for larger sizes.
Notes
Catalogue notes* Working moment = 2 x static moment. Ia/In = ratio between start-up current and maximum current. Several sizes are available with different mounting bolt patterns. Please contact sales office at Italvibras.
Ordering
SourceItalvibras General Catalogue 07-2019, page 20
PricingRequest a quote