The MVSS stainless steel series vibrators are characterized by their total protection from liquids, dusts, aggressive agents and contaminants, thanks to the stainless steel casing and external components
General
Italvibras code601526
TypeMVSS 15/700-S08
SeriesMVSS
Poles4
Speed1800 rpm @60Hz / 1500 rpm @50Hz
Power supplythree-phase and single-phase
Size30
CSAyes
Mechanical data
Static moment 50Hz [kgmm]286
Static moment 60Hz [kgmm]209
Centrifugal force 50Hz [kg]720
Centrifugal force 60Hz [kg]760
Centrifugal force 50Hz [kN]7.06
Centrifugal force 60Hz [kN]7.46
Weight 50Hz [kg]32.0
Weight 60Hz [kg]30.7
Electrical data
Max input power 50Hz [W]525
Max input power 60Hz [W]665
Max current 400V 50Hz [A]0.92
Max current 460V 60Hz [A]0.98
Ia/In 50Hz3.48
Ia/In 60Hz4.43
Single-phase electrical data
Single-phase Weight 50Hz [kg]25.0
Single-phase Weight 60Hz [kg]23.0
Single-phase Max input power 50Hz [W]450
Single-phase Max input power 60Hz [W]550
Single-phase Max current 220V 50Hz [A]2.15
Single-phase Max current 115V 60Hz [A]5.15
Single-phase Ia/In 50Hz5.44
Single-phase Ia/In 60Hz3.63
Dimensions
Fig.W
A [mm]382
B [mm]205
C [mm]205
D [mm]120
E [mm]170
Holes dia G [mm]17
Holes No.4
F [mm]17
H [mm]93.5
I [mm]100
L [mm]168
M [mm]158
N [mm]182
Capacitor 220V 50Hz [uF]-
Capacitor 115V 60Hz [uF]-
Cable entry threadM25x1.5
Single-phase dimensions (mm)
Capacitor 220V 50Hz [uF]16 running + 80 additional start-up only
Capacitor 115V 60Hz [uF]40 running + 120 additional start-up only
Series features
Power supplyThree-phase voltage from 24V to 690V, 50Hz or 60Hz or single-phase 100-130V, 60Hz and 200-240V, 50Hz (single-phase types are supplied without capacitor); suitable for use with an inverter from 20Hz to the base frequency with constant torque load profile.
Mechanical protectionIP 66 according to IEC/EN 60529.
Insulation classClass F (155degC), class H (180degC) on request.
Ambient temperatureFrom -20degC to +40degC. Versions for higher or lower temperatures are available on request.
CasingIn stainless steel AISI 304, ball burnishing surface treated to make the surface more hydrophobic.
CategoryII2D
Level of protectionEx tD A21 T...degC IP66 (Ex tb IIIC T...degC Db)
Temperature classsi veda tabella
EC certificateLCIE 05 ATEX 6163 X
Zones of use21, 22
Notes
Catalogue notes* Working moment = 2 x static moment. Single-phase table differs from three-phase table: Weight 50Hz [kg]: three-phase table '32.0', single-phase table '25.0'; Weight 60Hz [kg]: three-phase table '30.7', single-phase table '23.0'. Dimensions from page 47 (printed 45). Ia/In = ratio between start-up current and maximum current. Several sizes are available with different mounting bolt patterns. Capacitor symbols: open circle = Running capacitor, filled dot = Additional capacitor only for start-up.
Ordering
SourceItalvibras General Catalogue 07-2019, page 44
PricingRequest a quote